You have been registered for product and offer updates. System Sensor two-wire smoke detectors are marked with a compatibility . To stay in the know on upcoming news and announcements, subscribe. If a detector fails any of the above test methods, its wiring should be checked System Sensor makes no other express warranty for this smoke detecbe obligated to repair or replace units which are found to be defective because of damage, This system was used with Cox before, so no telling what all they did to it. Heat Sensor (Model 2WT-B and 4WT-B): 135F (57.2C) Freeze Trouble (Model 2WT-B and 4WT-B): 41F (5C) Operating Temperature Range: 2W-B and 4W-B: 32 to 120F (0 to 49C) 2WT-B and 4WT-B: 32 to 100F (0 to 37.8C) Operating Humidity Range: 0 to 95% RH non-condensing Storage Temperature Range: -4 to 158F (-20 to 70C) Diameter (including base): Reorient or relocate the receiving antenna. The smoke alarm was perfectly compatible with my 24-year old house alarm system. The 2W-B should work zones 1 and 2 since they are designed for system sensor 2-wire devices. of a 2W-MOD2 module. 2. Follow the steps in the Tech Bulletin below to check your current firmware version and update your device firmware if needed.. Refer to Preview PDF Download HTML 2W-B Datasheet (PDF) - Systemsensor advanced ideas. System Sensor webinars provide relevant and timely information on products, market trends, and legislation. Each i3 Series detector is supplied with a mounting base that can be mounted: 2.To a 312-inch or 4-inch octagonal box, or, 3.To a 4-inch square box with a plaster ring, or. St. Charles, Illinois 60174. 2009 System Sensor. Alarm Current: in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to List Price $134.00 Our Price $88.99 You Save $45.01 (34%) FireAlarm.com is always at the forefront of the fire & life safety industry offering the most diverse selection of technologies, offerings, and services - all for you to take advantage of FireAlarm.com is able to offer everything from Fire Alarm System Installation and Security Camera Surveillance, all the way to 24/7/365 Central Station Monitoring and Cellular Signal Transmission . The 2W-B smoke detector consists of a mounting base that can be mounted on a single gang box, a three and a half or four inch octagonal box or a four inch square box with a plaster ring. detector to finish the power-up cycle (see Table 2). The device uses photoelectric technology to detect smoke, while the fixed heat sensor activates at temperatures of 135F and higher. The System Sensor 2W-B is a 2-wire smoke detector and a member of System Sensors i3 Series of photoelectric smoke detectors. 135F (57.2C) Table 2: Power-up Sequence for LED Status Indication*, (if excessive electrical noise is present). 3825 Ohio Avenue, St. Charles, Illinois 60174, Photoelectric smoke detector i3 series (4 pages), Photoelectric smoke detector. I was planning on installing about 11 of these on a vista 21ip panel, what is the power draw I should account for when planning against the 650 mA allowance for the panel? ey+L)
l\q8e)2FWfQCCvBm
Yrsza G(
Vc Gz;?TP!k5UY6m}*i*OGWfMPMN O_\mV=}gj{sf! tLC>[PWGq9 p
Features include a universal mounting plate with a preliminary snap-in feature to hold the product in place for the screw attachment, 7 field-selectable candela settings for wall and ceiling mount devices, and rotary switches to select horn tone and volume settings. Its simple, step-by-step process makes it easy for users to configure panels and circuits from a variety of devices. At a minimum, cleaning should be performed annually. or system undergoing maintenance to prevent any unwanted alarms. System Sensor warrants its enclosed smoke detector to be free from defects in materials 30 % peak to peak of applied voltage Fire Alarm Systems | System Sensor L-series indoor horn/strobes System Sensor L-series indoor horn/ strobes www.boschsecurity.com u u Plug-in design with minimal intrusion into the back box u Field-selectable candela settings of 15 or 30 cd at 12 V or 15, 30, 75, 95, 110, 135, and 185 cd at 24 V u Horn rated at 88+ dBA at 16 V Rotary switch for horn tone and two volume settings Ready to learn more? *Refer to Electrical Specifications for start-up time in conjunction with panel alarm verification. When using the System Sensor 2W-B two wire smoke detector with a VISTA-20P or VISTA-21iP alarm control panel, you should wire the smoke detector to zone one. \kUb5{,P'Zwd**4C8X)z
System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. MFR PART # 2W-B SYSTEM SENSOR | 2W-B i3 Series Detector, 2-wire, 12/24 V DC, with Base MFR PART # 2W-B PART # 674092 Spec Sheet Email Print Minimum 1 Each In Stock Details References Shipping Description Installation ease. 4. Series 2W-MOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B are capable of generating a "maintenance. increase or alter the obligations or limitations of this Warranty. To a single gang box, or FREE delivery Mar 8 - 10. applicable state and local codes, and any special requirements of the local r^ lC-kr$EG_ KD/T=[ $y`j"lOmX LX6F(F;x*+yj#xgUB?fH"U*zN84Vz
D~m$y:67HqwZJ:RSYk4MU=';W(pg|s[pJTW/X
'@GWSYm
}Fs Upload manuals that we do not have and get. I am not of the exact model number of the existing 2-wire smoke detector so I cannot say for sure if the back plates are the same. Turn on: 1. Smoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. All wiring must be installed in compliance with the National Electrical Code, Photoelectric smoke detectors work with an alarm system, and when properly maintained and tested, can last for an indefinite period and do not automatically require replacement after a certain period of time like smoke alarms and CO detectors do. After all detectors have been installed, apply power to the alarm control Also, is your system currently monitored we do offer no contract low cost monitoring plans as low as $10/mth. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Place detector on the base and rotate clockwise. 7. The LED indication must not, be used in lieu of the tests specified under Testing. After power up, allow 80 seconds Replace the top half of the screen/sensing chamber by aligning the arrow performed and the system will be temporarily out of service. Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. to a 2-wire base, and a 4-wire head will only mount to a 4-wire base. Locking Pin. from the mounting base without the use of a tool. However zones 1 and 2 can support 16 on each zone. Verified purchase: Yes | Condition: Pre-owned. No. Ensure proper wiring and power is applied. To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure For convenience, the 2W-B mounting base can also be directly mounted to the ceiling using drywall fasteners. To test this please remove AC power and set the panel into alarm mode to see if the battery will support the system and report back. The i3 Series heads and bases are keyed so that a 2-wire head will only mount mounted: Proper wire gauges should be used. This notification is not a safety issue, but low battery warnings should be addressed promptly to avoid potential problems with system operations which may arise. Should it become necessary, the screen/sensing chamber is field replaceable. Hey, guys. 4W-B and 4WT-B are 4-wire photoelectric smoke detectors. The microprocessor, allows the detector to automatically adjust its sensitivity back, to the factory setting when it becomes more sensitive due to, contaminants settling in its chamber. Wiring Installation Guidelines When mounting the i3 Series, ensure that the head is mounted to the correct base. Enter a zip code, select a range, and choose a Distributor type to locate the nearest Distributor. manual are available from System Sensor at no charge. Enter your email address and check your inbox. Please refer to insert for the Limitations of Fire Alarm Systems 4. on the screen/sensing chamber with the arrow on the housing. (Figure 5). accept any interference received, including interference that may cause undesired operation. Band Color. item 3 System Sensor 2W-B 2WB i3 Series 2-wire Photoelectric Smoke Detector System Sensor 2W-B 2WB i3 Series 2-wire Photoelectric Smoke Detector. Two LEDs on the detector provide a local visual indication of the, After an initial power-up delay, the red and green LEDs will blink, synchronously once every ten seconds. All models incorporate a state-of-the-art optical sensing chamber and an advanced microprocessor. Models: 2W-B, 2WT-B, 4W-B, 4WT-B. The 2W-B smoke detector works with most Honeywell alarm control panels including the VISTA-20P and VISTA-21iP as System Sensor is a subsidiary of Honeywell. System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. Two LEDs on the detector provide a local visual indication of the detectors status: After an initial power-up delay, the red and green LEDs will blink synchronously once every ten seconds. Consult the dealer or an experienced radio/TV technician for help. NOTE: T Or should i plan on just running the wire directly out of the drywall? 50 Have feedback about a particular System Sensor product? Max. I am wondering if there is too much power connected to the panel for the sirens to sound. In order for this feature to work properly, the chamber must never be opened while power is applied to the smoke detector. Table 2: Power-up Sequence for LED Status Indication*, (if excessive electrical noise is present), *Refer to Electrical Specifications for start-up time in conjunction with panel alarm, NOTE: If, during power-up, the detector determines there is, excessive electrical noise in the system such as those caused by, improper grounding of the system or the conduit, both LEDs will, blink for up to 4 minutes before displaying detector status (see, After power-up has completed and the detector is functioning, normally within its listed sensitivity range, the green LED blinks, once every five seconds. We offer conventional and intelligent products for smoke detection, heat detection, fire and CO combination detection, and multi-criteria / multi-sensor detection, as well as bases and accessories. Some parts of this page is temporarily unavailable. 41F (5C) Consult NFPA 72, the local Authority Having Jurisdiction (AHJ), and/or applicable codes for specific information regarding the spacing and placement However, there is no guarantee that interference will not occur in a particular installation. 4.Direct mount or to ceiling using drywall fasteners (Figure 2). In wet or excessively humid areas, or next to bathrooms with showers. 1. A05-0395-007 4/09 #2132 SpectrAlert Advance Dimensions Model Description Wall Horn Strobes P2R* 2-Wire Horn Strobe, Standard cd, Red the temperature is below 41F. Notify the proper authorities when the system is back in service. Freeze Trouble (Model 2WT-B and 4WT-B): Peak Standby Current: Green LED. NFPA 72 requirements. This device complies with part 15 of the FCC Rules. avg., 100 A peak, Operating Temperature Range: 32 to 120F (0 to 49C), Operating Humidity Range: 0% to 95% RH, noncondensing. the removal of detectors before beginning construction or other dust producing activity. No agent, representative, dealer, or employee of the Company has the authority to It will take approximately 80 seconds for the item 6 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector. or exclusion may not apply to you. If the detector is within the listed sensitivity limits, the detectors red Figure 3a: Wiring Diagram, 2W-B and 2WT-B. Hello, I have a vista 20P (came with the house I bought) that has (4) 2 wire smokes wired in. 3. IMPORTANT: This detector must be tested and maintained regularly following NFPA 72 requirements. alarm verification. Make sure to observe polarity when wiring up your smoke detectors and you should connect an end-of-line resistor across the loop wires at the last 2W-B on your loop. For two-wire models To view our listings, please visit one of the following sites. They were an easy mount adapted to our smoke detecting system. The Companys obligation Leave everything as is at the panel and simply replace the smoke detector itself. When mounting the i3 Series, ensure that the head is mounted to the correct base. These are great replacement detectors. Once the mounting base is installed, the 2W-B smoke detector attaches to the base by simply inserting the head and turning it clockwise until it locks in place. i3 series (4 pages), I3 series. SMOKE System Sensor 2W-B Product Specifications: System Sensor 2W-B Product Compatibility: Plug-in detector line, mounting base included, Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling, Drift compensation and smoothing algorithms. Unlike traditional detection systems, Reflected Beam Smoke Detectors were designed for spacious rooms, open areas, and high ceilings; their innovative features make them popular choices for spaces like warehouses, atriums, arenas, and churches. 2WT-B and 4WT-B: Smoke Entry Test Cross-Reference: AV L-Series to SpectrAlert Advanced, Cross-Reference: Base/OEM Detector Compatibility, DOWNLOAD STROBE COVERAGE CALCULATION EXAMPLES AVFL220, DOWNLOAD CTA System Sensor Speaker GLL Files, DOWNLOAD SS BASE DETECTOR CROSS-REFERENCE, DOWNLOAD SS BASE DETECTOR CROSS-REFERENCE LEGACY. Twisted pair may be used to provide additional protection against extraneous electrical interference. Maximum Initial I see other smoke detectors that claim a lifespan of 10 years and recommend replacement at that time. System Sensor's product 2-wire compatibility listings are available onlinefor you to view and print out. and workmanship under normal use and service for a period of three years from date 32 to 120F (0 to 49C) Heat Sensor (Model 2WT-B and 4WT-B): Out of sensitivity Power must be removed from the detector Solid, After an initial power-up delay, the red and green LEDs will blink synchronously once every ten seconds. To view this information, simply choose a manufacturer and the appropriate model. gently blow the smoke through the detector until it alarms. 35 35 Volts Copies of this manual are available from System Sensor at no charge. NOTE: Before performing maintenance on the detector, notify the proper authorities that maintenance is being performed and the system will be temporarily out of service. View a list of all System Sensor locations worldwide. I have since replaced the battery, which has resolved the smoke error. 5. Two LEDs on the detector provide a local visual indication of the detectors status: IMPORTANT: This detector must be tested and maintained regularly following monoxide(co)/photoelectric smoke detector (4 pages), Manual will be automatically added to "My Manuals", Installation and maintenance instructions, Smoke Alarm System Sensor 4WT-B Installation And Maintenance Instructions, Smoke Alarm System Sensor 2WT-B Installation And Maintenance Instructions, Smoke Alarm System Sensor 2WTR-B Installation And Maintenance Instructions, Smoke Alarm System Sensor 2100ARFT Installation Instructions Manual, Smoke Alarm System Sensor 2251EIS Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor 22051E-RF Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor 2112 Installation And Maintenance Instructions, Smoke Alarm System Sensor FSB-200 Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor BEAM1224 Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor 2351E Installation And Maintenance Instructions, Smoke Alarm System Sensor DH100ACDCLP Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor 2100AT Installation And Maintenance Instructions, Smoke Alarm System Sensor 6500S Installation And Maintenance Instructions Manual, Smoke Alarm System Sensor i4 Series COSMO-2W Installation And Maintenance Instructions, Smoke Alarm System Sensor Innovair flex D4120A Installation And Maintenance Instructions Manual. Models 2W-B and 2WT-B also include an output that allows an optional Model The 2W-MOD2 installation manual may be downloaded from the %%EOF
No Contract Alarm Monitoring starting at $10 a month! list is available from System Sensor upon request. CAUTION Dust covers are an effective way to limit the entry of dust into the smoke detector sensing chamber. at the control panel or module. haha, Hi Dustin, Therefore, System Sensor recommends 130 Start-up Capacitance: Should By subscribing I give my consent to receive AlarmGrid e-mails about Vacuum or use canned air to remove any dust or particles that are present on both chamber halves. When the alarm goes off, both keypads seem like they short out for a second (the display panel goes blank the ready and arm lights flash, and it makes a weird beeping noise) then starts the alarm tone at the keypads only. z7$m9ymnsx.}]{~{^^}ltW? it become necessary, the screen/sensing chamber is field replaceable. When the detector is in the alarm mode, the red LED latches on. Notify the proper authorities that the system is in operation. best system performance, all wiring should be installed in separate grounded If they are not just take a photo of the connections and land what is connected to the positive connection the new plates positive and same with the negative. 21. With. system or the conduit, both LEDs will blink for up to 4 minutes before displaying detector status (see Table 2). In very cold or very hot areas. Operating Temp. 6.3 oz. Insert a small screwdriver or allen wrench (0.18 max.) 4.3 (21) $6371. This is because fire alarm control panels vary by 2W-B and 2WT-B, connect detectors only to compatible alarm control panels conduit; do not mix fire alarm system wiring in the same conduit as any other This feature ensures that your security system will not experience nuisance false alarms. Loop verification is provided by the EZ Walk loop test feature. 5.3 inches NOTE: If, during power-up, the detector determines there is excessive electrical noise in the system such as those caused by improper grounding of the